Pentair Mastertemp 400 Error Codes - When I turn on the heater.

Last updated:

Pentair MasterTemp 460736 Operation & Installation Manual (56 pages) 120/240 VAC NATURAL GAS/LP GAS MasterTemp Pool & Spa Heater. Get advice from other pool owners who faced similar issues. For variable speed pool pumps, try putting the pump speed up a notch Check for any clogs or backups causing poor water circulation. Double-check all the wiring connections and replace any damaged wires. Wait one minute and see if heater fires. I’ve replaced the SFS 3 times now and each time it works for a couple of minutes and then throws E05 again. to/391FMioAsk your Questions or search from our database of answers: https://askthepoolguy. if you have any questions please contact us through our website at: https://www. Answered in 21 hours by: Pool and Spa Expert: Billy. D "SPR" Fault code - Heater not starting. The control board only has LED11 (Service Heater) and LED7 (Not sure what this is, it's right in the corner). Optimum Pool Technologies Inc …. However, like any appliance, they can sometimes encounter issues that result in error co. The following instructions will guide you through Pentair MasterTemp 400 Ignition control module replacement. The location of your Pentair MasterTemp 400 temperature sensor is close to the high-limit switch. Press Select to enter the menu. Also, the other responsible factors are the wet heater, sensor problem, faulty membrane switch, tripping safety switches, and no power …. The Pentair Mastertemp 400 Error code ‘Ps’ indicates a potential problem with the pool pump pressure. It will also work with all Sta-Rite Heaters. Second Opinion] Hello my name is***** have a stay right 400 pool heater I have no codes and when I hit the off button it does not shut off any ideas … read more Daniel Scott. david wade wbz Dirty filters can obstruct water flow, leading to reduced heating efficiency. Hello - I am having Problems with my Pentair Mastertemp 400 heater. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. If the resistance is out of range, you need to replace the sensor. This is usauly caused by a flow issue or a bad thermal regulator causing the water to remain in the exchanger and over heat. Thread starter AndyFla; Start date Nov 25, 2018; Jump to latest Follow Reply Forums. Texting is my preferred format. MasterTemp ® Heaters offer all the efficiency, convenience, and reliability features. Fact Friday: Pentair MasterTemp 400 Pool & Spa Heater. The Pentair Mastertemp 400 service system light is an important indicator of the pool heater’s operation. H 9-5-12 MASTERTEMP® Pool and Spa Heater Installation and User's Guide 7 SAFETY INFORMATION Section 2. With a ⅞” deep socket, loosen up the thermistor and take it out. Comments9 · PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR · Pool Troubleshooting and Repair - Service heater ·. Error codes on the automation panel. Fortunately, some error codes may have simple solutions you can do on your ow. Save money and energy with the MasterTemp High-Performance Heater. When breaker is turned off and then back on a code 888 then 12A then r14 comes on but then screen … read more. Hi I have a Pentair 400 Spa Heater Model 460776 Serial 11183440800156. when i turn on the pump, there is nothing on the display. The green spa light is on and then the display alternates …. My pentair mastertemp seems to be working except temperature reading on the heater keeps going up when on, to 300 degrees or higher. Heater does not turn off, but reading keeps going up, up, up, I'm a …. Recently the heater is turning on by itself and shows code 328 on the display. This common issue not only disrupts your plans but can also signal underlying problems needing immediate attention. After my dog ate the conduit & wires which I replaced. Ensure that all the connections are tight. To contact us, schedule a service or learn more about your pool visit us at: https://www. These are the following: Examine the flow rate of the water to see if it exceeds the minimum. As of today, it will turn on, the fan is blowing, and you can hear the heater ignite and enter full operation, but in less than one minute, it shuts off and flips into service mode. What I liked about the Pentair 460737 MasterTemp Performance Pool Heater. Pentair Aquatic Systems AU/NZ – Head Office 1-21 Monash Drive, Dandenong South, Victoria 3175 – Australia † 1300. Lift control panel assembly off of support. Put the new one in and turn it to stabilize. Keep your pool at the perfect temperature with this top-quality heater. Intake and exhaust pipes must be minimum of 36" (91. It calls for heat, heat starts for maybe 5-10. The Major League Baseball season is falling. When i first turn on my pool heater (sta rite max e therm 400 hd) i get Therm rite sta starite manifold Sta rite max e therm 400 manual. The FENWAL 35-6x Series are 24VAC Microprocessor Based Gas Ignition Controls designed for use in all types of gas-fired equipment and appliances. The FENWAL 35-6x Series are 24VAC Microprocessor Based Gas Ignition Controls designed for use in all types of gas-fired …. Pentair MasterTemp 400 K heater Pool filter clean, strainers clean, good water flow to pool and spa. You're probably wondering what's gone wrong and how you can fix it. ETI™ 400 HEATER (CONT’D) REPLACEMENT PARTS BURNER SYSTEM REPLACEMENT PARTS (CONTINUED) 11 11 25 10 22 Condensate Neutralizer Cartridge (Optional, P/N 475612 sold separately). Whirlpool washers are renowned for their durability and efficiency. Pentair Mastertemp 400 Pool Heater. My pool heater pentair mastertemp 400, is turning on every time my pool pump turns on and it reads 128 R13. The ags sensors on your pentair pool heater can also cause ags errors. samsung tablet cases with keyboard; 2/0 copper wire 3 conductor; round cutter machine paper; how to reduce humidity in a commercial building; foam seat cushion near netherlands. I have a pentair 125 pool heater that keeps throwing the AGS code. To 553-5000 Technical Support: 800. The same is true if what you use is in your pool is the Raypak pool heater. HLS is high limit switch, it's a safety switch for the outlet of heater, how hot the water is coming out. I will tell you what formats for common handlers exist and why it is better to agree on a single format with the backend than to fence a new solution every time Receive Stories fro. To replace the wire harness on a MasterTemp® or Max-E-Therm® Heater: FIG. Pentair MasterTemp 400 Wrong Temperature [5 Easy Fixes] We will now take an in-depth look at the causes. MasterTemp 400 Control Board Replacement. Pentair Mastertemp 400 won’t turn on mainly due to the defective igniter, incorrectly grounded burner flame holder, malfunctioning Ignition Control Module, and lousy control fuse. 3 and 4) * 460754 Gas Orifice Kit – Propane, Model 300 (Incl. Make sure the pump is on and that the cords are plugged in securely. The gas valve inlet’s inappropriate gas pressure is another reason why your Pentair mastertemp 125 won’t ignite. Code MasterTemp 175NA +5% Gas Orifice - NA 460796 1 472741 XN MasterTemp 175NA –5% Gas Orifice - NA 1 472742 ZN MasterTemp …. , MOORPARK, CA 93021 • (805) 553-5000 ALL INDICATED PENTAIR TRADEMARKS AND LOGOS ARE PROPERTY OF PENTAIR INC. Step 4: Now take the new ICM and put it in the Junction Box chamber. Trane furnaces are known for their reliability and efficiency, but like any mechanical system, they can experience issues from time to time. Consult your local building and health codes for more information. I’d start with backwashing or cleaning your filter first, make sure pump pot is clear of debris etc. Optional Smart Heater Bypass valve control diverts water flow when the heater isn’t needed to help save up to 35% in yearly operational costs. Aug 14, 2023 · Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Low gas pressure is the #1 cause of heat exchangers sooting. Try reseating the connectors on the SFS. to/391FMioHeaters are really important in Mic. Contractor's Assistant: I understand that you're having an issue with the Pentair Mastertemp 400 service heater light. Replacement of Thermal Regulator on Mastertemp 400 Pool/Spa HeaterPart #: 38000-0007S (Thermal Regulator Only)Part #: 77707-0010 (Thermal Regulator w/spr. me/amateurcarguyPlease like/comment/share/subscribe/donate!Hey Youtube this is a quick …. Jan 12, 2023 · To contact us, schedule a service or learn more about your pool visit us at: https://www. Remove the tube and check for blockages or holes. The Jandy control panel has an option, 1 button for pool heat, 1 button for spa heat. Jun 7, 2022 · Solution: Check the gas valve and make sure that it is turned on completely. judge mathis bailiff net worth Encountering issues with your Pentair MasterTemp 400 can be frustrating, especially when it's not heating your pool as it should. ER 2: This code means there's a problem with the heater's flow switch. Jul 21, 2013 47,472 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60. Remove air orifice from the blower (Fig. Pentair MasterTemp 400: Fixing Ignition Lockout Issues; Pentair MasterTemp 400: Fix a Flashing Heating Light… Pentair MasterTemp 400: Fixing the Service Heater… Pentair MasterTemp 400 Fixes: Solve Not Heating Issue; Pentair MasterTemp 400 Issues: Fixes for On-Off Cycling; Pentair MasterTemp 400 …. Ask the Pool Guy Changed status to publish May 9, 2018. Ultra-High ASME® certified performance in a compact, quiet and eco-friendly design for your commercial application. Pentair MasterTemp Low NOx Commercial Swimming Pool Heater - Electronic Ignition - Natural Gas - 400,000 BTU ASME - 460775 Call (888) 836-6025 or contact us for pricing and to purchase. Posted by u/il-liba - 1 vote and 1 comment. Jul 21, 2013 46,931 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60. Make sure your pool heater’s igniter is not too cold, and it is warming up to fire up. how to find out my ppp loan number. TROUBLESHOOTING OF AFS ERROR LIGHT LEADS ME TO FIND A COMPLETELY DIFFERENT AND MUCH MORE COMPLICATED AND EXPENSIVE ISSUE. You may also have an issue with the exhaust flue. Serious mal-function of the burner can occur which may result in loss of life. When operating, the inlet pressure should not drop by more than 2" wc nor to less than 4" wc. Manual is suitable for 5 more products: MASTERTEMP 200HD MASTERTEMP 400 HD MASTERTEMP 300HD MASTERTEMP 200 MASTERTEMP 300. Pentair pool products mastertemp 200hd operation & installation manualPentair asme master temp pool heater, 250,000 btu, propane gas Pentair pool products mastertemp 250k btu/hr installation and userMastertemp kit adapter indoor venting pentair btu heater americanbestpoolsupply. DON'T ASSUME YOU HAVE A DEFECTIVE AF. 1 and the latest edition of the National Electrical Code, NFPA 70 (US). TIME TO HEAT 20,000-GALLON POOL BY +10°F TIME TO HEAT 600-GALLON SPA BY +30°F. etg 80 hour myth reddit Comments7 · MiniMax NT Pool Heater error code E02 · PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR · Just Put Su. The Pentair MasterTemp common problems include- ignitions failure, temperature problems, heater keeps shutting switch, display not working and the electric not turning on. Error code E06 Pool heater is showing the code E06 on the display. Pentair MasterTemp 400 units typically have diagnostic systems that convey issues via specific codes. ), or standards CSA B149 – INSTALLATION CODES FOR GAS-BURNING APPLIANCES AND EQUIPMENT and/or local codes and Standard CSA C22. If the water temperature sensor and the wiring are good, that would indicate a bad control board. Here are five easy steps to fix it ASAP. Pentair Mastertemp 250 Leaking Water. Swimables Control Board Kit Compatible with Mastertemp & Max-E-Therm Pentair Pool and Spa Heater 42002-0007s- Compatible with All NA and LP Series Pool/Spa Heater Electrical Systems - Made in USA. 2 cm) of vertical clearance above the for drive disassembly and removal. Make sure the water temperature is less than 60°C. The on-board diagnostic computer, or OBD comput. One common issue with the Pentair Mastertemp 400 is low heat output, which can result from various factors. Both models are identical same heater. If you're looking for help fixing your Pentair Pool Heaters, look no further! Our comprehensive Pentair Pool Heaters error code guide will explain common iss. Clean the skimmer baskets and the pump basket, turn pump on, wait for it to totally fill filter, removed the air from the filter, and wait 2-3 mins to turn on heater. High performance heater (56 pages) Page 2 For a list of all ETi heater replacement parts, and their Digital associated part numbers, consult the latest Pentair product Display catalog or ETi 400 Installation and User's Guide. Ask the Pool Guy 213 Posted May 9, 2018 0 Comments. Sensor is replaced and heater works li. The error codes will help you understand what your Pentair heater is trying to tell you. There are several things you can do to troubleshoot a pentair pool heater that is not igniting: 1. This item: Pentair Mastertemp 400K Btu Heater 460805. 47 Get it as soon as Friday, Jan 12. I agree, no sense in replacing parts if it’s so old and it’s on its last legs. *Ahorros basados en pruebas de laboratorio realizadas utilizando el calentador MasterTemp 400 en conjunto con la bomba IntelliFlo VSF y el Kit de derivación (bypass), que incluye una válvula IntelliValve controlada por el. Hello , This thread has been inactive for over 60 days. Could be you don't have gas getting to the pilot, no spark to ignite the pilot or your ignition is not reading the flame. Ensure that your filters are clean, the pump is running normally, and there are no blockages in the lines. Features: Cupro-Nickel Heat Exchanger. Press the "Mode" button to set the temperature. E05: E05 errors can be due to things like a sooted exchanger (fuel delivery, venting), scaled up exchanger (water side), or a low water flow. MasterTemp ® Heaters offer all the efficiency, convenience, and …. If the gas is too rich then you may have to check the gas regulator setting. I have a MT 250 running the heat on the hot tub in the gym I work for and I keep getting a random E01 code and the heater shuts down. emcee; Aug 10, 2023; Everything Else; Replies 2 Views 207. Find a mistake in your report? You’ll want to contact the bureaus, stat. It contains helpful tips and advice from other pool owners who have faced the same issue and how they resolved it. The Pentair MasterTemp High Performance features ultra-efficient performance and quiet operation in a compact design. Disconnect the main water line and turn off the heater before properly cleaning the pipes. LED indicator light for the High Limit Switch(HLS) would blink. Trouble Free Pool offers helpful tips and advice. Built-in mixing system reduces condensation possibilities. This membrane controls the many functions on the Pentair Mastertemp 400 pool. MasterTemp Heater - 400K BTU - Natural gas. It's very slick, until you try installing extensions that haven. Clean the gas pipes properly if they are clogged and do not forget to turn off the valve before cleaning. BioShield® UV System (Lamp and Quarts Sleeve only) manufactured after October 1, 2023. Hello, Thank you for using JustAnswer; my name is***** am sorry you have issues with your Pentair Mastertemp Pool & Spa heater. Boiler and Pressure Vessel Code, having a capacity equal to the Btu/hr rating of the heater. It does heat the spa about 1 degree every cycle. service system & service heater lights are off heater set p … read more. Solution: You need to inspect the wiring of your Pentair MasterTemp 400. Therm mypoolyardWhen i first turn on my pool heater (sta rite max e therm. Remove and inspect to see if it is blown. alyssa fluellen husband age Troubleshooting Heater will Not Fire Troubleshooting Replacement Parts. This 42002-0024S Stack Flue Sensor replacement fits Pentair MasterTemp pool and spa heater electrical systems; Compatibility. The four bolts on the heating jackets must be removed. Most of the time its caused by improper installation. Max-E-Therm heaters are available in a range of heat output capacities from 175,000 BTU to 400,000 BTU. The error can also occur if a system file that the computer requires to o. The heater came up in spa mode, showed a rapidly increasing temperature. Pentair MASTERTEMP 200 HD Installation And User Manual (68 pages) POOL AND SPA HEATER (FOR OUTDOOR USE ONLY) Brand: Pentair | Category: Heater | Size: 10. I have a Pentair Mastertemp 400 heater that short cycles for 5-10 seconds at a time. The Pentair Mastertemp 400 Troubleshooting Manual is an invaluable resource for anyone who owns a Mastertemp 400 pool heater. This could include anything from a dirty filter, clogged. It was summer so I waited till now to fill we are under warranty …. Good morning, Quartz readers! Good morning, Quartz readers! Gmail has been down for many users. It’s often associated with a communication breakdown between the different components of the heater. Condensate Neutralizer Cartridge (Optional, P/N 475612 sold separately). It is pretty easy to change out, which will correct the problem. That must be replaced since it is reading the water temp at 125. Solution: Examine the water pipes and make sure that they are clean. 2, and Pentair recommends that users. 200HD (200 MJ/h) 300HD (300 MJ/h) 400HD (400 MJ/h) FOR YOUR SAFETY - This product must be installed. How to fix it: Check that pool pump is receiving enough water. Step 1: Remove the heater’s left side panel. Pentair MasterTemp Error Codes: Our Pentair MasterTemp troubleshooting guide starts with the error codes shared by both models. 3 and 4) * 77707-0441 Gas Orifice Kit – Propane, Model 400 (Incl. The higher the BTUs, the higher the heating power, and the faster your pool can heat up. Discover comfort and expertise on our HVAC blog. Maytag washers are known for their durability and reliable performance. Pentair mastertemp 400 common problems are low water flow, pool heaters won't turn on, and thermal regulator issues. Comments107 · How to Replace the Heater Core on a Pentair MasterTemp · PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT . Jun 13, 2017 · Pentair Master Temp 400 - got an HLS error light on the back of the gel touch circuit board of the heater control panel. ID DESIGNATOR FOR PENTAIR POOL AND SPA MAX-E-THERM HEATERS Example: 123 4 FUEL TYPE = N = NATURAL GAS LP = PROPANE GAS 200 (200 [BTU/hr), 300 (300 [BTU/hr) or 400 (400 [BTU/hr) HD = HEAVY DUTY MODEL N Heater Identification Information (HIN) Heater Data Rating Plate Location The heater data rating plate is …. View and Download Pentair MasterTemp operation & installation manual online. If the issue persists, the pressure switch may need to be replaced. This video tells you how to check/set the Stack Flue Sensor (SFS) temperature. OR ITS GLOBAL AFFILIATES IN THE U. Resetting Duraflame Heater And Fixing E3 Code: Simple; How To Fix Mr. Use an open-end wrench to tighten the last half-turn. Experiencing unexpected shutdowns with your Pentair MasterTemp 400 can be quite frustrating, especially when you're looking forward to a relaxing swim. And remember, you must ensure that the water flow is not obstructed. 604342 | Manufacturer SKU: 42002-0007S. com Fax: (800) 284-4151 Kit Contents The following items are included in the water/air temperature sensor replacement kit: Temperature Sensor Assembly - P/N 520872 • Temperature Sensor, 10k Temperature Sensor - P/N 520326 • Temperature Sensor, 10k Ohms, 40 ft - P/N 521583 • Temperature Sensor, 10k Ohms, …. Low gas pressure can be why your Pentair MasterTemp 400 keeps. Check for proper gas pressure and ensure the gas valve is fully open. Max combustion intake length matches max venting length caculated above. to/3C2Oj49Flume Sensor 2: https://amzn. Refer to the ETi 400 Installation and User’s Guide for speciic installation procedures. Eco-friendly MasterTemp® is certified for low NOx emission and outperforms industry standards. This an natural gas model, 460732, which someone modified for a propane feed long before I bought the house. veneer sheets lowes Dual ignition systems for models greater than 750,000 BTU. For every $1 of natural gas that’s piped into the heater, 96 cents goes directly to heating your pool. Pentair MasterTemp Low NOx Pool Heater – 400k BTU (Natural Gas) $ 4,199. I have a pentair mastertemp 400 heater connected to a new pentair pool and spa controller with pentair pump. 668 400HD (400 MJ/h) 460944 460947 FOR YOUR SAFETY and state codes before installing the MasterTemp. SPECIAL INSTRUCTIONS TO OWNER: Retain this manual for future reference. Can someone explain what these codes mean?. Step 2: You then need to take apart the Max-E-Therm heater from the system. 12 Pentair Heater Error Codes, Their Meanings & Solutions. Jan 6, 2022 · I have a pentair mastertemp 400 that's hooked up to an easytouch system. Set water flow to maintain a temperature rise of 30°F +/- 5°F between the water inlet temperature and the water outlet temperature from the heat exchangers. Pentair Mastertemp 400 Error Code 128 R13 Store, 54% Discount, rayconindustries. Its use will reduce service calls and chance of injury and will lengthen. If using 4" pipe, Combustion Air Intake Kit (P/N 475971 -- sold separately) MUST be installed. Turns out that it wasn't the problem, it was a corroded Thermal Regulator. No codes lit on back of the board. MasterTemp Heater: Remove left side panel from the heater (Fig. Home - Trouble Free Pool | Trouble Free Pool. If you own a Whirlpool washer, you may have encountered error codes at some point during its operation. Then got AFS light on control board. Interestingly, both Pentair and Sta-Rite use the same part number for their control boards. I'm getting a service code of E05 on my Pentair pool heater. It is showing the code on the board. However, keep reading our Pentair pool heater. Inaccurate Temperature Control or Display. to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy. Replacement for Pentair MiniMax Heaters. Pool/Spa Heater Repair- Error Code Pentair Pool Heater E05 Error Code - How to PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH . Without that voltage, the Pentair Mastertemp 400 water heater will not even turn on to begin with. pentair mastertemp 400 error codes 20'' heavy barrel 223 wylde. The relief valve must be installed horizontally. I keep turning it off everytime I check it and then when check back after couple of day … read more. Refer to your heater’s documentation to decode these messages, which can provide clearer direction on potential ignition system faults. Step 2: Disconnect the system from the Max-E-Therm heater. These codes are the pool heater’s way of communicating specific problems, and each code corresponds to a potential fault within the system. After reading the manual, I took a pick of the back of the. Otherwise it's a bad sensor or damaged wires. The manufacturers' names and part numbers have been used for reference purposes only. Plumbing aligns to MasterTemp® High Performance Heater, for easy drop in replacement. I have pentair mastertemp 400 that is only a couple of years hello, i have pentair mastertemp 400 that is only a couple of years old. Compatible Replacments for: Pentair MasterTemp (All Models) & Max-E-Therm (Models SR200, SR333, SR400) Heaters ; Manufactured by Optimum Pool Technologies ; NOTE: This is a compatible aftermarket replacement part. The unit starts up then shows 128 then r=8 and then finally reads 128. The MasterTemp® 125 heater requires an external power source (120/240 VAC 60 Hz) to operate. The poster here pretty much cannot tell you RPM to run your pump without knowing what pump you have and I don't see that mentioned anywhere if you have a one and a half horsepower pump or a 3 horsepower pump I mean 2100 RPM is way plenty. West: 213-291-9276 Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878 or 954-866-1644. The heater fires up with no problem runs for about a minute (longer than most people saying theirs runs for like 10 seconds) - then …. May 3, 2014 57,315 Laughlin, NV Pool Size 6000 Surface Fiberglass Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-40. the heater did not come back on and i …. 400K BTU/HR (MasterTemp) 460775 460776 400K BTU/HR (Max-E-Therm) 460763 460764 MasterTemp® and Max-E-Therm® POOL HEATERS BYPASS ACCESS PLUG KIT (472648Z) INSTRUCTIONS [ASME MODELS - ONLY] Pentair Water Pool and Spa, Inc. In the event you have filed an IRS return with the wrong Social Security number, you can wait for the IRS to catch the error and contact you, or, you can correct it yourself by fil. The part number for the sensor is Pentair 42002-0024S. Reset the swimming pool main power supply. ohio craigslist puppies Brand: Pentair | Category: Heater | Size: 10. dopesick nation frankie face scars. For applications using Propane Gas, this conversion kit is required. This video shows the removal and di. Which MasterTemp heater also comes equipped with the Pentair multifunction temperature controller welche shows, at a glance, and proper functioning of the heater. If the LED display shifted it may have pulled a wire from the control board. 1 Pool Heater Turns On But Does Not Heat; 1. craigslist harford county Take a few minutes to gain a greater understanding. The MasterTemp stack flue snsor trips when exhaust temps reach more than 350 degrees. Error Code E05: Stack Flue Sensor Is Open. Thermistor Part #: 42001-00536SHLS (High Limit Switch) Part #: 42001-0063S. Very easy to swap out, less than ten minutes. Got an r13 128 error code on Pentair MasterTemp 400 Natural gas pool heater. I have changed the air blower, the ignitor, and have had the gas company ch …. I have a Pentair MasterTemp 250 which had a fried fan and didn't want to start. Thermostat malfunctions can lead to incorrect temperature readings and irregular heating. Availability: Contact us for availability. It's a fairly powerful heater and when working correctly, it'll quickly get the spa or pool to a nice temp. Ensure that your pool pump is sending water to the heat pump. Some other problems that Pentair Mastertemp 400 pool heater users face are the blower not working, not heating, not igniting, not turning on, knocking noise. garrygoeson : make sure temperature setting is above water temperature. Service system indicates low flow/ dirty filter. This short video shows you how to navigate around the new interface and menus of the new 2021 Pentair MasterTemp Pool Heater. Heater supplied w/240 from breaker panel and what I'm assuming to be the Molex connector (square white 9 …. Doctor and hospital bills are riddled with errors. old time pottery stuart photos AquaPro 1100e Pool Heater Heat Pump Not Heating - No Error Code PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR. Its powerful heating capabilities make it ideal for both residential and commercial applications. Feb 8, 2023 116 Missouri Pool Size 25611 Surface Vinyl Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60. Canon printers are known for their reliability and high-quality printing. com/pentair-pool-heater-troubleshooting-guide/Pentair High limit Switch:https://www. A) - 01-24-07 For MasterTemp Model No. As a pool owner myself, I know. When your Pentair MasterTemp 400 pool heater's blower fails to kick in, it's not just an inconvenience; it's a barrier between you and your perfect swim. Error codes are the first step in diagnosing any en. I have a Pentair Mini Max 400 Natural Gas. However, like any electronic device, they may encounter issues from time to time. MasterTemp ® Heaters offer all the efficiency, convenience, and reliability features you. E01 – This indicates an ignition failure. When the light turns on, it indicates that there is a problem with the unit and requires maintenance or repair. Allow the heater to cool for at least 30 minutes before proceeding to the next step. C 4/2017 ETi 400 High Efficiency Pool and Spa Heater Installation and User's Guide Page 30 Step 1 & 2 latch lock Upper Blower Inlet Air Orifice Step 3 Street Elbow Lower Blower Inlet Air Orifice Figure 23. The fan works and air starts moving through. Apr 18, 2020 · Mastertemp Pool Heater Parts: https://amzn. My Pentair Mastertemp 400 is defaulting to 95 degrees when ever it is turned on in spa mode. I have a Jandy RS pool controller and a Pentair MasterTemp 400 NG heater. Possibly a bad internal bypass or thermal regulator, but not likely in a new heater. Apr 22, 2022 · These are the following: Examine the flow rate of the water to see if it exceeds the minimum. Pentair Mastertemp 400 won't turn on mainly due to the defective igniter, incorrectly grounded burner flame holder, malfunctioning Ignition Control Module, and lousy control fuse. ETI™ 400 HEATER (CONT'D) REPLACEMENT PARTS BURNER SYSTEM REPLACEMENT PARTS (CONTINUED) 11 11 25 10 22 Condensate Neutralizer Cartridge (Optional, P/N 475612 sold separately). JACUSTOMER-w2vctfkb- : Already tried that, no luck. Solution: Check the gas valve and make sure that it is turned on completely. MasterTemp Heater - 400K BTU - Propane gas. If the problem persists, contact a professional for repair or replacement. However, like any other appliance, they can sometimes encounter issues that require troubleshooting. These actions will ensure the heater light is functioning properly and heating the water. Quick video showing the Optimum Pool Technologies replacement of the Pentair Mastertemp high limit switch. Pentair MasterTemp 400, changed thermistor, HLS, Flue Stack Switch, AGS, and control board. Pool and spa heater (56 pages) Is there a three (3) alpha numeric (Page 45) numeric fault code displayed on the LCD? GO TO Dianostic LEDs page 45 ETi 400 High Efficiency Pool …. You could also take the heat exchanger for …. 620974 | Manufacturer SKU: 42002-0024S. apn settings for unlimited data 2020 If the SFS reads 80, then flashes to 40, then back to 80, then the 80/40 reading and E05 indicate that the board is not getting a reading from the sensor. That intellichlor only needs 20 or 25gpm, I can't remember. Replacing your broken stack flue sensor is easy! Just follow these steps: Turn off the filter pump and all electrical power to the pool heater. To schedule a service, ask us questions, or to. and follow the prompts for technical support. The service system light is on, and it has two red lights on, on the reverse side of the motherboard. Certified for outdoor and indoor installations. I show you how to replace and install the Pentair Mastertemp 400 membrane pad. TM MasterTemp CERTIFIED ® ® POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS INSTALLATION and USER’S GUIDE MODELS Natural Propane 200K BTU/HR 460730 460731 250K BTU/HR 460732 460733 300K BTU/HR 460734 460735 400K BTU/HR 460736 460737 SPECIAL …. cub cadet oil change kit tractor supply. Turn on the power supply switch or flip the circuit breaker back on. Pentair Water Pool and Spa, Inc. Also make sure to cut off breaker heater for a minute and then kick back on. Pentair pool heater troubleshooting. This is because the thermostat regulates the pool’s water temperature, signaling your heater to cycle on or off. Plumbing connection — ideal for smaller bodies of water, including aboveground pools, spas and inground pools up to 15,000 gallons. alberg 30 for sale craigslist How long does a pool heater last? A good pool heater like STA-RITE lasts around 12 to 20 years. If the reset procedure did not solve the issue with your Pentair Pool Heater, it may be time to seek professional help. It’s engineered to be ultra-quiet as many pool heaters tend to be noisy. This is usually caused by too low a flow rate. Have your installer submit it to your local warranty team and they will fix the issue for free. 2i, Ștefăneștii de Jos, Ilfov pelonis space heater manual. Please be patient; it can take several minutes for me to respond. But don't worry, you're about to learn how to troubleshoot and resolve it. Mar 15, 2022 · If you're looking for help fixing your Pentair Pool Heaters, look no further! Our comprehensive Pentair Pool Heaters error code guide will explain common iss. You will need a screwdriver for this. We have 3 Pentair MASTERTEMP 400 HD manuals available for free PDF download: Installation And User …. garden winds replacement canopy top cover ar 10x12 gazebo 350; lamentation of christ. You could also take the heat exchanger for servicing. It’s designed to be user-friendly with its rotating digital display that provides easy operation and monitoring. The air flow switch is connected to the draft inducer blower with a plastic/rubber tube. Keep scrolling and read our Pentair MasterTemp 400 troubleshooting guide to fix your heater ASAP. 82% energy efficiency is highest in class. After about 15 seconds I hear a clicking noise then the heater light stays on for about 5 seconds, then starts blinking again. After running for about 15 minutes, the display showed E05. I have a Pentair MasterTemp 400. I am getting an e01 code on my pentair mastertemp 400 heater. Error code 0x80004005 most commonly occurs when a computer’s registry or essential files become corrupted. and serviced by authorized personnel, qualified in. LG dishwashers are known for their reliability and efficiency in getting your dishes clean. I acknowledge that all natural gas and propane heaters are final sale and must be installed by a certified gas technician; self-installation can void manufacturer's warranty. predator vertical shaft The ETi 400 is designed to accommodate the features that make your pool fun. Efficiently heat your pool with the Pentair MasterTemp® 400K Natural Gas Heater EC-462028 (460736). Check the gas valve and gas supply for any issues. Test the HLS continuity using a multimeter. Pool heater failing to ignite gas. If you own a Kenmore oven, you may have encountered error codes at some point. Learning to spot and fix them could save you thousands on your care. The heater turns on, the temp sensor on the heater r … read more. Once flow is verified, power off heater. All MasterTemp® 125 heaters are designed with a direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. If this does not cure the problem, you will have to hire a professional to service your heater. EMEA – Head Office: Industriepark, Wolfstee, Toekomstlaan 30, 2200 Herentals - Belgium. Check pressure switch adjustment. Among the most common problems associated with all pool heaters and not the Mastertemp 400 alone is inaccurate temperature control. Your pool heater's refusal to start is often a sign of this all-too-common issue. Step 2: Remove all of the thermistor’s electrical connections. co/d/9q50OXp If you have a leslies pool supply in your area, they may have it too. sync drive tmobile Contractor's Assistant: Sometimes pool issues that that you think will be really complicated end up being easy to fix. Eco-friendly MasterTemp Heater is certified for low NOx emission and outperforms industry standards. This service heater has a 400,000 BTU output, making it well-suited for pools of all sizes. The Pentair Mastertemp 400 Error Code PS is an indication of a low pressure switch malfunction. When I disconnect from the Aqualink the heater works fine manually. You just disconnect the two wires and remove it with a wrench. PART NO: 460737 (Part no: EC-462029). I'm having problems with my Pentair Mastertemp 250. It's possible that there's air in the pipes. Press both arrows on the IntelliValve actuator to do this. Locate the reset button, usually on the control board or near the display. Ignition failure error code: if you see the error code “e01,” it …. I have a Stayrite Max-E-Therm 400 gas heater that was installed when I bought my house in March 2009. With its advanced technology and user-friendly features, it ensures optimum performance and hassle-free maintenance. Go on you tube and watch the installation video, very quick and easy. 3 Replacing Internal Bypass Valve; 2. However, like any other appliance, they can sometimes encounter issues that may result in erro. Disconnect the ags sensor from the control board. Brand: Pentair Pool Products | Category: Heater | Size: 3. The theme is missing the style. Set Point Controls START OF EVERY POOL SEASON: 1. Then it shuts off for about 30 secs comes back on and does the same thing. Calibration Errors: Over time, the heating system may need recalibration to ensure that the temperature readings match the. Pentair MasterTemp 400 natural gas heater won't ignite. if not wait for tech to come out. GS3680 industrial vacuum cleaner wet&dry · Pool Troubleshooting and Repair - Service heater · Sta-rite 333 trouble tips · PENTAIR MASTERTEM. I will do all I can to help you with your question. Reason 1: The flow of water to the heater has reduced. The meter should be a least 400 cubic feet per hour for the heater plus anything else that might run at the same time. The inlet pressure to the gas valve should be between 4" wc and 14" wc. For better visibility, consider Starting A New Thread. Three potential causes addressed: High limit sensor, thermal regulator, bypa. Remove the side panel just below the heater control panel. Pentair Mastertemp 400 Heater would heat on and off, intermittently. 5 yrs - Answered by a verified Pool and Spa Expert. Purchased from Pool Supply Unlimited however they w …. omg live periscope Read our article to troubleshoot your Pentair MasterTemp 400. New bronze header design allows for easy access to the thermal regulator and bypass valve service without use of special tools. Action Purpose Tool Required; Resetting the Heater: Clears transient errors: None: Inspect Ignition Sequence: Identifies ignition issues: Visual Inspection. Disconnect the wires to the ICM. This high eficiency improves your heat up time and reduces your energy cost as shown by the formulas below: = Pool/Spa Volume X 8. The bE or bE2 error codes indicates that a. ice services north slope jobs After that, yes, you would have to press the pool or spa button and set the temp for it to start up. For Air Intake Kit order part number 461031. Smart connectivity via the Pentair Automation Systems enable you to manage pool functions anytime, anywhere. Your Pentair MasterTemp 400 wrong temperature being displayed can be caused by a faulty thermistor, wet heater parts, broken thermal regulator, bad manifold bypass, and malfunctioning control board. SWITCHDOCTOR Pool Heater Manifold Assembly Kit with O-Rings for Pentair MasterTemp 175, 200, 250, 300, 400 Sta-Rite Max-e-Therm SR200, SR333, SR400 77707-0205 77707-0206 77707-0014 This manifold comes with everything shown in the picture as well as the thermal regulator cap. The following instructions will guide you through the entire process of replacing the Ignition Control Module, ICM of your Pentair MasterTemp 400. We judge ourselves for so many things. The valve should then turn to position 7. 1 Canadian Electric Code, part 1. The Xerox N2125 fuser assembly should be replaced after every 200,000 page impressions. THIRD PARTY REGISTERED AND UNREGISTERED TRADEMARKS AND LOGOS ARE THE PROPERTY OF THEIR. Mar 8, 2024 · Low Heat Output. The required flow rate for a heater is going to be different from a salt cell. 200HD (200 MJ/h) 300HD (300 MJ/h) 400HD (400 MJ/h) FOR YOUR SAFETY – This product must be installed. Aug 20, 2021 · If your heater is displaying an E05 or E06 error code there is a simple fix. MasterTemp swimming pool heater pdf manual download. Whirlpool washers are known for their reliability and efficiency in cleaning clothes. husqvarna 6 bushel double bagger for 42 in tractor manual. Fits through standard doorways. Warning and Safety Instructions The MasterTemp® pool heaters are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual. 77707-0054 Pool Heater Igniter Gasket Kit Compatible with Pentair MasterTemp 400 Pool Heater Parts,Replacement for Pentair MasterTemp/Max-E-Therm Pool and Spa Heater 【Compatibility】77707-0054 Igniter kit is compatible with Pentair Sta-Rite, Max-E-Therm, MasterTemp 200HD/300HD/400HD and Max-E-Therm 400 400 HD, 400 ASME pool & …. To troubleshoot the service heater light on your pentair mastertemp 400 pool heater, first, clean the filter and ensure there is no blockage in the venting system. We would like to show you a description here but the site won’t allow us. Jul 31, 2022 · The voltage that the Pentair Mastertemp 400 water heater needs are 24 VAC. I've already changed the HLS, AGS switch and stack flue sensor Pool and Spa Expert: CertifiedPoolPro , replied 8 months ago. to 4:30 PM Eastern Time/Pacific Time) Web sites: www. You MasterTemp® heater will indicate when it is time to replace the High Limit Switch when the "HLS" LED is displayed. What does that mean? The heater comes on for about 45 seconds and then shuts down with that code. Your Pentair MasterTemp 400 wrong temperature being displayed can be caused by a faulty thermistor, wet heater parts, broken thermal regulator, bad manifold …. The high-limit switch should be replaced. Installation in Canada must be in accordance with the latest CAN/CGA-B149. Press the Menu button then press the Down arrow until BYPASS is selected. How To Fix It: Examine the heater to make sure that the flow of water is not restricted in any way and clear the chamber of all the accumulated water. Ask the Pool Guy Changed status to publish June 20, 2018. Also make sure if you have an external bypass in plumbing it is set to run the heater. If the problem persists, contact …. mansfield pro fit steel xd installation instructions pdf Warning and Safety Instructions The MasterTemp® pool heaters are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this …. Vessel Code, having a capacity equal to the Btu/hr rating of the heater. Heavy Duty Heater 400 Regency Forest Dr | Cary, NC 27518 | United States | 800. Could be you don’t have gas getting to the pilot, no spark to ignite the pilot or your ignition is not reading the flame. Step 4: Inspect The Ags Sensors. Manual is suitable for 5 more products: MASTERTEMP 200HD MASTERTEMP 400 HD …. The industry’s first heat pump charged with non-ozone depleting refrigerant, R410A. If you have a Pentair Master Temp 400 heater with a red service system light, you may want to read this thread on Trouble Free Pool. The heater, when installed, must consult your Pentair dealer. Is the service heater light on your Pentair Mastertemp 400 …. To install the valve, use a 3/4" x 3-1/2” All Pentair trademarks and logos are owned by Pentair, Inc. disclaims proprietary interest in marks and names of others. how much is a carton of newport cigarettes at walmart This switch must sense vacuum from the blower or the burner won't fire. After about 20 more seconds the heater light goes out. Check for blockage at the the draft inducer where the tube connects. Ships from and sold by Dealsupply. We recently gave the filter a good cleaning and now the heater won’t stay running. Heater Big Maxx 2 And 3 Flashes [Solved] Troubleshooting Mr. Check the back of the board the next time it doesn't light, the SFS LED should be lit if you see E05. It is important to comply with these codes, many of which directly regulate the installation and use of this product. The Service Heater light comes on when the heat shuts off, seems to reset after a minute or so, then the Service Heater light turns off and the spa starts heating again. There are four screws that need unscrewing. Pentair MasterTemp 400 Keeps Shutting Off [9 Easy Fixes] Resetting Duraflame Heater And Fixing E3 Code: Simple; How To Fix Mr. The heater turns on and runs for 10 seconds and turns off and throws the light on. New postings here are unlikely to be seen or responded to by other members. (wc is water column the measurement using a Manometer to measure the gas pressure) Ask Your Own Pool and Spa Question. I bought my house this past summer and has a pool equipped with a Pentair heater Mastertemp 400 p/n 460736. The following are some signs that may indicate ags error on pentair pool heater: Error code displayed on the heater. When breaker is turned off and then back on a code 888 then 12A then r14 comes on but then screen goes blank. Only the heating LED will be lit if the heater is heating. About a minute or 2 later it will turn on again and will do the same thing. Turn the power back on, and the heater should reset. 1 – Canadian Electrical Code, Part 1 (Canada). Also get the dreaded E05 which I know is the stack temp sensor. What it means: the 24 VAC supply voltage to the heat pump circuit board is low. If your heater is displaying an E05 or E06 error code there is a simple fix. ER 3: This code means that the heater has overheated. 120/240 VAC NATURAL GAS/LP GAS MasterTemp Pool & Spa Heater. Windows XP: If your Windows XP installation is acting up, sometimes a fix is as simple as tweaking a registry key. The display shows the current water temp and shows the flame 🔥 icon. Max-E-Therm Heater: Unbolt the four bolts and separate the jackets halves. used utility trailers for sale in pa Don't hesitate to get in touch with us today at 585-223-8650 or through our contact form to learn more about how we can help you bring your vision to life. Common Issues With Pentair Pool Heaters. The heater will reset and work fine for. Manual is suitable for 4 more products: MasterTemp 175 MasterTemp 200 MasterTemp 300 MasterTemp 250. We have 3 Pentair MASTERTEMP 400 HD manuals available for free PDF download: Installation And User Manual, Brochure. Quick video showing the Optimum Pool Technologies replacement of the Pentair Mastertemp stack flue sensor. Fixing a Pentair Minimax heater that turns on heat and then shuts off after a minute. I am trying to warm up the pool and the spa however when i set the temperature on the easytouch pad, the mastertemp 400 heater …. to/391FMioAsk your Questions or search from o. The Temp sensor is located on the upper left side of the manifold as you're facing the water inlet and outlet connections. You are receiving an r13 code on your Pentair Mastertemp 400. When i first turn on my pool heater (sta rite max e therm 400 hd) i get Therm rite sta starite manifold …. The code you are seeing on your Pentair Master temp 400 is a boot-up code that we see when the heater first fires up; if your heater is stuck with this on the display, you have a failed main control board which is underneath the keypad. When I pres "Heater" and Up buttons, I get "16n" on the screen, by pressing up button, also get "PS", "AFS" and. Abr 20th, 2023 ; hilton sandestin lanai room; tom sharkey first wife; pineapple bubly discontinued. pinocchio 1993 vhs archive There are 3 screws to remove before lifting off the panel. 6 cm) of side and rear clearance for motor disassembly and removal. If pressure is way low, check pump flow/ clogged impeller. 273 might be the stack flue temperature, which is displayed when you push the pool on or the spa on button. Which type heater do you select in drop down menu on pentair home app under intelliconnect for a mastertemp 250? all it shows is mastertempmor a mastertemp 125 … read more Grant Narayan. How to fix it: Check that transformer supply voltage is within 208 – 260 volts. A faulty thermistor can result in the E01 error message popping …. Gas Shutoff Switch Replacement for Pentair® Max-E-Therm® & MasterTemp® - Replaces 42001-0025S Replacement for Pentair® MiniMax® Heater Pressure Switch - Replaces 473605 CA Prop 65 Warning: Products made by Optimum Pool Technologies may contain chemicals known to the state of California to cause cancer and birth defects or other. ERR IGN could be igniter, lack of gas flow, FENWAL failure, board failure, rodents chewing on wires. This guide is taken from this manual to provide more clarity. Your heater would possibly soot if all the fuel is not burnt. Hopefully, you will get the solution. Please understand that I schedule my phone calls through our chat sessions if. I have the Pentair Mastertemp 400. Question: I see the non-pentair branded ones on Amazon for $22 bucksbut the pentair or sta-rite OEM ones are triple that on other websites. Check to make sure the heater pilot tubing is intact and not clogged. 96% of the heat generated during the combustion process is transferred directly to pool water. Los calentadores MasterTemp están disponibles en un rango de capacidad de salida de calor de 175. The "E01" code means you have an open water temperature sensor. So far, I've replaced the ignition coil, cleaned the flue/flame sensor and checked all …. s AU/NZ – Head Office 1-21 Monash Drive, Dandenong South, Victoria 3175 – Australia • 1300. I don't see any codes other than the initial 888 128 r13 when the heater turns on After about 15 seconds i hear a clicking noise then the heater light stays on for about 5 seconds, then starts blinking again. When a problem occurs, the furnace’s co. Fits Pentair Mastertemp Pool And Spa Heater Electrical System ; Customer ratings by feature. In this section, we will explore the various components and features of the Mastertemp 400 and how they contribute to its overall. I just bought a new Fenwal and it does the same thing as the old one. Rather, it’s a sign that the heater is about to turn on. It’s time to replace the high-limit switch. In case you have questions about your Pentair pool heater, you can comment below. Pentair MasterTemp Membrane Pad Kit | 472610Z. Pentair mastertemp 400 service heater light how to fix. There's more transparency in the release than the Small Business Administration had planned. Alerts pushed to a smart device to keep you updated on heater performance and real-time status. When your Pentair MasterTemp 400 signals a service heater light, it's alerting you to a potential issue that needs your attention. , Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133 -. Pentair mastertemp 400 won't light service heater light comes on r13. Refer to the ETi 400 Installation and User's Guide for speciic installation procedures. Inadequate water flow, dirty filters. 475612 - ETi 400 Condensate Neutralizer Replacement Kit - ETi 400 heater produces condensate while in operation. cloud maid love nikki Pentair Aquatic Systems™ and MasterTemp. My temperature on my Pentair Mastertemp HD 400 was reading 126 and the unit would not fire up because the max temp is 104. Mopar4Life · 23K views ; The girl renovate the old dilapidated house into a . Understanding what causes this light to turn on is crucial for maintaining your pool's comfort and extending the life of your heater. You might also need the membrane pad if that looks bad, but I would try the control board first. if i cycle off and then backon the circuit breaker, the heater turns …. to contact us, schedule a repair, or learn more about your poolvisit our website at: https://www. 1 - Canadian Electrical Code, Part 1 (Canada). Heat exchanger, pentair mastertemp/max-e-therm 400, nat. When I turn on the heater the Service heater light comes on. Pentair MasterTemp Low NOx Heater - Electronic Ignition - HD Cupro Nickel - Natural Gas - 400K BTU ASME - 461021 Call (888) 836-6025 or contact us for pricing and to purchase. co2 cylinder refill adapter; vietnamese sweet bread; read it sewer scene book excerpt; henry golden boy receiver cover. Rotating digital display - can be installed in three directions. I just replaced the thermistor, and it fired and ran for about 2 min and shit off … read more. My pentair mastertemp 250 will turn on and ignite, will run for about a minute and then turn off. Understanding the causes of an ignition lockout is crucial for a quick fix. veggietales 1997 Errors on the heater control panel. Ma We judge ourselves for so many things. If your pool has water flowing through the heater and the gas line is installed properly then you have done your part. For example, A Mastertemp 400 is going to need a minimum of 40gpm, but let’s say you have an intellichlor that you’re basing your flow off of. Check that correct pressure relief valve has been installed (if code requires it) Check for correct location of chemical feeder. The compact design allows the heater to be tucked away for a sleek, aesthetic pool and spa equipment pad layout. Onboard diagnostics or OBD/OBD-II codes are those dreaded engine error codes that only trained auto mechanics seem to understand. The Pentair Mastertemp 400 Afs Light pool heater features a digital display that allows for easy monitoring of the temperature settings. Note: Never exceed the maximum recommendation flow rate for the connecting pipe. 475971 - ETi 400 Indoor Direct Air Intake Kit - For applications in which the ETi 400 will be installed indoors using a Direct Air Intake, use this kit for …. Page 1 Pentair Water Pool and Spa, Inc. Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code, ANSI Z223. The Pentair Mastertemp 400 Afs Light is the perfect pool heating solution for those looking for reliable and efficient performance. Ultra-High Performance in a Compact, Quiet & Eco-Friendly Design. I am keeping a pool for a rental property at 86 degF with the pump running continuously. BTU Input 400000 British thermal unit. By clicking "TRY IT", I agree to receive newsle.